NDR-RS
NDR Lamp Memory Master Station with External Control Capability for Rescue Assitance
NDR-10RS NDR-20RS NDR-30RS NDR-40RS
NDR-10ARS NDR-20ARS NDR-30ARS NDR-40ARS
- INSTRUCTIONS -
The NDR-nRS Lamp Memory System is designed for use with the NE-NVP-RA Rescue Assistance sub stations.
The NE-NVP-RA provides communication and call status indication for applications with ADA requirements for
Areas of Rescue Assistance. The NE-NVP-RA features Braille signage, a large red call button, and "call placed"
and "help coming" LED indicators. The sub station flush mounts into a 3-gang masonry-type box, or surface
mounts in the SBX-NVP. Tamper proof screws are provided, along with a wrench for installation. Remote lamps
can be added for better visibility of a station's status. The NDR-nRS master station is equipped with a door
release button and a reset button to reset calls at the master station. The NDR-nRS has outputs to activate an
external device, such as a CCTV camera when the associated sub station is selected, or selectively controlling
the corresponding door strike or maglock.
WIRING DIAGRAM: SYSTEM USED FOR CCTV CAMERA CALL-UP
NDR-20RS
NE-NVP-RA
NE-NVP-RA
NE-NVP-RA
1
2
3
Red
Red
Red
Green
jumper
Green
jumper
Green
jumper
Leave green
jumper intact
~
20
Blu
Pur
Blk
Yel
Org
Blu
Pur
Blk
Yel
Org
Blu
Pur
Blk
Yel
Org
E
S
H
External
Terminal Block
1
2
RY-PA
Closure for Station #1
BLK
#3
YEL
RY-PA
#2
Closure for Station #2
YEL
BLK
3
~
20
Normally Open contacts remain
closed as long as master has sub
station selected.
RY-PA
YEL
Closure for Station #3
BLK
#1
L
PS-2410A
Terminal Block
+
-
+
-
DUAL FUNCTIONS FROM EACH CHANNEL:
Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
RY-PA
1
BLK
Momentary closure #1
YEL
YEL
#1
RY-PA
#2
Constant closure #1
BLK
1 Diode (1N4001)
L
Individual Components for System:
NDR-nRS Master station with selective contact output capability (10, 20, 30, 40)
NDR-nARS Master station w/hndst andcontact output capability (10, 20, 30, 40)
ND-20AS 20-call Add-on Selector with selective output capability (Require PS-2410A)
ND-40AS 40-call Add-on Selector with selective output capability (Requires PS-24E)
RY-PA
#1
2
Momentary
closure #2
YEL
YEL
BLK
NDR-RS Master
RY-PA
#2
Constant
closure #2
RY-PA
PS-2410A24V DC, 1A Power Supply for 10-20 station systems
PS-24E 24V DC, 2A Power Supply for 30-40 station systems
Relay for selective output (1 per station requiring external contact)
BLK
H
NE-NVP-RA Vandal proof sub station with call status indicators and braille signage
NDR-RS TERMINAL DEFINITIONS:
+
-
1~40
E
S
Positive 24V DC
Negative
Station number
Common communication
Sends "call placed" tone to sub
IMPORTANT:
1. RY-PA must be used for each additional contact
to isolate AC voltage from the intercom circuit.
2. Extra contact connections and L are on separate
terminal block. NDR-30/40RS have two terminal blocks.
H
Resets call signals at sub when RESET
button is pressed.
Pg. 1
|
ACP EP Memory Camera Accessories EPMM 256 PLUS User Manual
ADC Network Card Pro Patch User Manual
Aiphone Thermostat PAA 100F User Manual
Alamo Lawn Mower 02974374P User Manual
Alesis CD Player Vocalist User Manual
Alto Shaam Oven 1200 S Series User Manual
Alto Shaam Oven Electronically Operated Ovens User Manual
Alto Shaam Refrigerator 1000 mr1 User Manual
Amana Refrigerator ATB1822MR User Manual
BB Electronics Surge Protector 232HSP User Manual